1959 S. 4130 W., Bldg A Unit G, SLC UT 84104Visit our shop
Roll-Up Doors AND Commercial Doors
(801) 716-2411

Commercial Garage Door Sensor & Photo Eye Repair Utah

Photo Eyes

Door Won't Close? Check the Eyes

Same-Day Service

If the door opens fine but only closes while someone holds the button, suspect the photo eyes first. Since 2010, UL 325 has required commercial operators to close on constant pressure or use a monitored entrapment device, usually a photo eye.

Request Service

Tell us about the door and what it's doing.

Photo Eyes
Operators
Side-Mount Motors
Spring Changes
Cables
Rollers
Panels & Slats
Track & Drums

What We Check & Fix

Sensor Service

Alignment & Lenses

Carts, pallets, and stored equipment knock eyes out of line, and brackets loosen over time. Dust, cobwebs, and moisture block the beam too. We clean the lenses, realign the pair, and tighten the mounts.

Wiring & Power

Dark sensors usually mean no power, or a cut, stapled, or corroded low-voltage wire between the eyes and the operator. We trace and repair the run, or replace sensors that are damaged.

Correct Height

The beam has to sit level, within 6 inches of the floor. Eyes raised to protect trucks leave people unprotected, so vehicles get extra sensors, edges, or loop detectors instead.

Why the 6-Inch Rule Matters

Safety Standards

Industry guidance published by DASMA is direct: photo eyes used for primary entrapment protection “must be installed parallel to the floor and no higher than 6" above the finished floor.” Mounting them higher can also bring an OSHA violation. We never bypass or rewire photo eyes just to force a door closed.

Test them monthly: start the door down, break the beam, and make sure the door reverses all the way open.